<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-18 02-00-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.90 MHz 4/5, 65 dBuV RFM
Pilot RDS Phase Difference
7.1 kHz 4.2 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 72 kHz 10060 1,2425
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,4 dBr 8,04 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RFM " F212 0 (No PTY) 1 0 0 1 2:00, 18.09.2025
RT
"RFM - PAUL SIMON - You can call me al "
AF EON
91.3, 93.3, 93.6, 94.3, 95.7, 97.3, 99.8, 101.6, 101.7, 102.4, 102.6, 103.8, 103.9, 104.1, 106.2, 107.0, 107.4 MHz -
FM Scope Station: 103.90 MHz, signal: 4/5 (65 dBuV) Max at: 72 kHz MIN: 16 kHz % above 75 kHz: 1,2425 Acquired: 2025/09/18 1:59:47 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,3 dBr MIN: 7,4 dBr AVE: 8,04 dBr % above 10,2 dBr: 0,0 Last value: 7,8 dBr (2025/09/18 1:59:47) Station: 103.90 MHz, signal: 4/5 (65 dBuV) 01:53 01:54 01:55 01:56 01:57 01:58 01:59 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality